Concord Time Cube Relays are compact and versatile timing devices designed to deliver precise time-based control in industrial and automation systems. Engineered for reliability and flexibility, these relays provide accurate delay functions for switching operations, sequencing, and process control.
With multiple timing ranges and compact plug-in design, Time Cube relays are ideal for applications requiring space-saving and efficient timing solutions.
✔ Compact Plug-in Design
✔ Adjustable Timing Functions
✔ High Precision Operation
✔ Reliable & Stable Performance
✔ Easy Installation
✔ Long Service Life
Maintains output after signal removal.
Precise and adjustable delay settings.
Ensures stable electrical operations.
Easy panel installation.
Designed for industrial environments.
Manufactured by Concord.
| Current type | AC / DC (50 Hz) |
|---|---|
| Nominal voltage | 20 V |
| Current consumption on input control B1 AC / DC | - / 0.2 mA | 0.2 mA / 0.2 mA |
|---|---|
| Current consumption on supply A1-A2 AC / DC | 12 mA / 12 mA | 6 mA / 6 mA |
| Frequency range | DC | 0; 40 ... 60 Hz |
| Nominal voltage | 9,5 … 18 V AC / DC | 20 … 65 V AC / DC |
| Operating voltage range | 9.5 ... 17 V AC / DC | 20 … 65 V AC / DC |
| Power consumption AC / DC | 0.2 VA / 0.4 W | 0.4 VA / 0.4 W |
| Threshold voltage on input control B1 AC / DC | 9 V / 9 V | 18 V / 18 V |
| Current consumption on input control B1 AC / DC | - / 0.2 mA | 0.2 mA / 0.2 mA |
|---|---|
| Current consumption on supply A1-A2 AC / DC | 12 mA / 12 mA | 6 mA / 6 mA |
| Frequency range | DC | 0; 40 ... 60 Hz |
| Nominal voltage | 9,5 … 18 V AC / DC | 20 … 65 V AC / DC |
| Operating voltage range | 9.5 ... 17 V AC / DC | 20 … 65 V AC / DC |
| Power consumption AC / DC | 0.2 VA / 0.4 W | 0.4 VA / 0.4 W |
| Threshold voltage on input control B1 AC / DC | 9 V / 9 V | 18 V / 18 V |
| Current consumption on input control B1 AC / DC | 0.2 mA / 0.2 mA |
|---|---|
| Current consumption on supply A1-A2 AC / DC | 2 mA / 2 mA |
| Frequency range | 0; 40 ... 60 Hz |
| Nominal voltage | 90 … 265 V AC / DC |
| Operating voltage range | 90 ... 265 AC / DC |
| Power consumption AC / DC | 0.5 VA / 0.5 W |
| Threshold voltage on input control B1 AC / DC | 75 V / 75 V |
| Conductor cross section control / main circuit | 2.5 mm2 |
|---|---|
| Housing material | PC |
| Ingress Protection | IP 20 |
| Nominal screw torque control / main circuit | 0.5 Nm |
| Operation temperature | -25 … 60 °C |
| Storage temperature (no ice) | -40 … 85 °C |
| Weight | 35 g |
| Approvals | UKCA,CE,cURus,EAC |
|---|---|
| Standards | IEC/EN 61812-1 |
| Timing range | 0.2 s … 3 s / 2 s … 30 s / 0.2 min … 3 min / 2 min … 30 min |
|---|---|
| Timing scale | 3 s / 30 s / 3 min / 30 min |
Download the detailed technical datasheet for Off Delay Time Lag Relay, including specifications such as:
Helpful documents on the “CT2-A30/L UC20-65V”
CAD drawings and technical layouts are available for panel design and system integration.