My Blog

Time Cub

Time Cube Relays

Concord Time Cube Relays are compact and versatile timing devices designed to deliver precise time-based control in industrial and automation systems. Engineered for reliability and flexibility, these relays provide accurate delay functions for switching operations, sequencing, and process control.

With multiple timing ranges and compact plug-in design, Time Cube relays are ideal for applications requiring space-saving and efficient timing solutions.

✔ Compact Plug-in Design
✔ Adjustable Timing Functions
✔ High Precision Operation
✔ Reliable & Stable Performance
✔ Easy Installation
✔ Long Service Life

Key Features

Controlled Delay

Maintains output after signal removal.

Accurate Timing

Precise and adjustable delay settings.

Reliable Switching

Ensures stable electrical operations.

Compact Design

Easy panel installation.

Durable Build

Designed for industrial environments.

Trusted Quality

Manufactured by Concord.

Time Cub

Current type AC / DC (50 Hz)
Nominal voltage 20 V
Current consumption on input control B1 AC / DC - / 0.2 mA | 0.2 mA / 0.2 mA
Current consumption on supply A1-A2 AC / DC 12 mA / 12 mA | 6 mA / 6 mA
Frequency range DC | 0; 40 ... 60 Hz
Nominal voltage 9,5 … 18 V AC / DC | 20 … 65 V AC / DC
Operating voltage range 9.5 ... 17 V AC / DC | 20 … 65 V AC / DC
Power consumption AC / DC 0.2 VA / 0.4 W | 0.4 VA / 0.4 W
Threshold voltage on input control B1 AC / DC 9 V / 9 V | 18 V / 18 V
Current consumption on input control B1 AC / DC - / 0.2 mA | 0.2 mA / 0.2 mA
Current consumption on supply A1-A2 AC / DC 12 mA / 12 mA | 6 mA / 6 mA
Frequency range DC | 0; 40 ... 60 Hz
Nominal voltage 9,5 … 18 V AC / DC | 20 … 65 V AC / DC
Operating voltage range 9.5 ... 17 V AC / DC | 20 … 65 V AC / DC
Power consumption AC / DC 0.2 VA / 0.4 W | 0.4 VA / 0.4 W
Threshold voltage on input control B1 AC / DC 9 V / 9 V | 18 V / 18 V
Current consumption on input control B1 AC / DC 0.2 mA / 0.2 mA
Current consumption on supply A1-A2 AC / DC 2 mA / 2 mA
Frequency range 0; 40 ... 60 Hz
Nominal voltage 90 … 265 V AC / DC
Operating voltage range 90 ... 265 AC / DC
Power consumption AC / DC 0.5 VA / 0.5 W
Threshold voltage on input control B1 AC / DC 75 V / 75 V
Conductor cross section control / main circuit 2.5 mm2
Housing material PC
Ingress Protection IP 20
Nominal screw torque control / main circuit 0.5 Nm
Operation temperature -25 … 60 °C
Storage temperature (no ice) -40 … 85 °C
Weight 35 g
Approvals UKCA,CE,cURus,EAC
Standards IEC/EN 61812-1
Timing range 0.2 s … 3 s / 2 s … 30 s / 0.2 min … 3 min / 2 min … 30 min
Timing scale 3 s / 30 s / 3 min / 30 min
Approvals

Download the detailed technical datasheet for Off Delay Time Lag Relay, including specifications such as:

  • Operating voltage
  • Timing range
  • Contact configuration
  • Mounting details
  • Wiring diagram

Data Sheet

Helpful documents on the “CT2-A30/L UC20-65V”

Change Instruction

CAD drawings and technical layouts are available for panel design and system integration.